Firebreak Home Run the self-check
The smoke filtration guide · five parts
Smoke Guide · Part 4 of 5

Building It: Parts, Wiring and Automation

The parts list, the wiring that makes the system fail toward protection, and the automation that means you never have to think about it.

Disclosure: This guide contains affiliate links. If you buy through them, I earn a small commission at no extra cost to you. I only link products I'd use in my own install.
Disclaimer: This guide involves modifications to your home's ventilation system and low-voltage/line-voltage wiring. Ductwork changes affect house pressurization, which matters if you have combustion appliances (gas furnace, wood stove, gas water heater). If you're unsure about any step — especially electrical work — hire a licensed electrician or HVAC technician. You are responsible for compliance with local codes.

Materials List

Core system (all tiers)

ItemPurposeApprox. cost
Suncourt ZC damper (normally closed) — sized to your duct (links in the sizing table)Straight run; closes during smoke mode / power loss$78–95
Suncourt ZO damper (normally open) — sized to your duct (links in the sizing table)Filter loop; opens during smoke mode / power loss$78–95
Galvanized tees ×2, duct, fittingsBypass loop$40–80
Custom or off-the-shelf filter housingHolds the 3-stage bank$50–150 DIY; see HVACQuick CFB inline filter boxes for pre-built options
MERV-8 pre-filter (16×16 commodity size, shares the carbon face)Stage 1 — protects carbon & final filter$10–15
Carbon panel or DIY carbon tray (16×16 face, 2” bed) + bulk coconut shell carbon, 4×8 meshStage 2 — VOCs and gas-phase pollutants$50–150
Final particle filter (per your tier)Stage 3$15 (MERV-13) to $300 (HEPA)
DIY carbon-tray caution: Loose granular media must be securely contained so carbon dust and granules cannot migrate into the ventilation system. Use appropriate retaining screens and a housing designed to prevent bypass. Follow the carbon supplier's handling and safety information. The electrical control shown below includes line-voltage components; use properly rated enclosures, wiring methods and overcurrent protection, and follow local electrical code.

Fail-Toward-Filtration Wiring

The control concept below uses one relay to switch the damper transformers so that loss of control power returns the dampers to the filtered path. Exact 120 V and 24 V wiring must follow the actuator/transformer instructions, component ratings, and applicable electrical code; use a qualified electrician where required.

120 Vhouse circuitRelayShelly 1 Gen424 Vtransformer24 VtransformerZC damper — straight runnormally closedZO damper — filter loopnormally openOPENCLOSEDEnergized — normal mode: straight run open, filter loop shut. Air takes the free path.
Why one relay, and why these two damper types. A single relay can drive both transformers so the dampers are commanded together. The selected damper arrangement returns to the filtered path when control power is lost, covering failures such as a tripped control breaker, failed relay or Wi-Fi outage. Verify the actual spring-return/normal position of the specific dampers before relying on this behavior.

Losing control power defaults the outdoor-air path toward filtration; it does not guarantee that the ventilation system itself continues operating, nor does it make every other failure mode safe.

Automation (Optional but Worth It)

ItemPurposeApprox. cost
Shelly 1 Gen4 WiFi relayHome Assistant–controlled switch for both dampers~$25
PurpleAir outdoor sensorReal-time local PM2.5 — the automation trigger~$240–300
PurpleAir indoor sensor (Touch)Verifies your filtration is actually working~$210
Aranet4 (or similar NDIR CO2 monitor)Tells you when the house needs fresh air~$190
AirGradient ONEVOC trend monitoring — a rough indicator of changing gas-phase conditions$138 kit / $230 assembled

The automation logic is simple: when your outdoor PM2.5 sensor crosses a chosen threshold, Home Assistant de-energizes the relay and the system switches to filtered mode. Add hysteresis (for example, different trigger and release thresholds) so the dampers do not repeatedly switch when readings hover near the line. The threshold is an operational choice, not a universal health boundary. Even without automation, a manual switch can provide smoke mode.

Why the AirGradient? Activated carbon does not provide a simple universal end-of-life signal. An indoor VOC sensor can help identify changes in gas-phase conditions, but it cannot reliably diagnose carbon saturation: readings can change because of cooking, cleaning products, occupants, humidity and other sources. Use it as a trend indicator, not as a breakthrough alarm.

Total Cost

Pick your configuration and the estimator adds up the line items from the tables above:

What it costs to build
Final particle stage
How you switch it
Sensors
Ventilation unit
Estimated total—
Added up from the line items in the tables above, not from a headline figure. Ranges are the spread in those tables; your ducting, housing approach and local prices move the real number. Filter housing assumes a DIY build — a pre-built inline box costs more.

The point of this approach is targeted retrofit rather than replacement of the entire ventilation system. Actual costs vary widely with equipment, duct layout, filter availability and labor.

← Part 3Sizing & feasibilityPart 5 →Living with it